{"product_id":"capnospot-pneumothorax-decompression-indicator","title":"Capnospot Pneumothorax Decompression Indicator","description":"\u003c!-- Capnospot Pneumothorax Decompression Indicator — GEO-optimized product description --\u003e\n\u003cdiv style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#121212;max-width:860px;margin:0 auto;line-height:1.65;\"\u003e\n\n  \u003c!-- Direct Answer Block --\u003e\n  \u003cdiv style=\"margin:0 0 28px;padding:16px 20px;background:#f5f4f0;border-left:4px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0;font-size:15px;color:#121212;line-height:1.6;\"\u003eThe Pneumeric Capnospot® is a novel colorimetric CO₂ detection device that attaches to any commercially available needle decompression catheter via standard Luer fitting to provide objective, visual confirmation of successful pleural entry within seconds. When the needle enters the pneumothorax space, CO₂-rich air produces a clear color change from blue to yellow — replacing the subjective \"gush of air\" assessment that fails in up to 50% of cases in trained professionals. Winner of the 2023 EMS World Expo Innovation Award.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specifications Table --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eKey Specifications\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eSpecification\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eDetail\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003ePneumeric Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eDevice Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eColorimetric CO₂ Detection Indicator (Visual Carbon Dioxide Detection Device)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMechanism\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eColorimetric capnography — color changes blue → yellow in presence of CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eConfirmation Speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e\u0026lt;5 seconds from pleural entry\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eStandard Luer fitting — compatible with all commercially available decompression needles and catheters\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eCompatible Devices\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eNAR ARS® (10 Ga. \u0026amp; 14 Ga.), NAR Enhanced ARS®, NAR SPEAR®, and any Luer-compatible catheter\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e3.2 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSmall, lightweight, portable; functions in low-light conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eFDA Statement\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e\"Used for more accurate placement of pneumothorax decompression devices than the current standard of care auditory assessments\" (FDA)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eAward\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e2023 EMS World Expo Innovation Award Winner\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eImportant Note\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNeedle\/catheter NOT included — attach to your existing decompression device\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eProduct Overview\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe standard of care for confirming successful needle thoracostomy has historically been auditory: providers listen for a \"rush\" or \"hiss\" of air as the needle enters the pleural space. This method is subjective, highly susceptible to environmental noise (helicopters, gunfire, sirens, crowd noise), and dependent on a tension large enough to produce audible flow. Research has consistently documented a 20–50% failure rate for needle decompression in well-trained professionals — a failure rate that contributes directly to preventable mortality. Data shows that successful therapy reduces 24-hour mortality by approximately 25%.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe Capnospot transforms this ambiguous, high-stakes assessment into an unambiguous binary result: the device turns from blue to yellow when carbon dioxide — which is elevated in the tension pneumothorax space compared to atmospheric air — contacts the colorimetric indicator. The color change occurs within 5 seconds of pleural entry, providing the fastest objective confirmation currently available at the point of injury. If the catheter loses patency or migrates out of the pleural space, the Capnospot reverts to its original blue color — alerting the provider immediately to reposition or replace the catheter.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe science behind this approach is well-established: the gaseous composition of a tension pneumothorax has an elevated partial pressure of CO₂ relative to normal atmospheric air, making colorimetric capnography an ideal confirmation test. The device was initially designed and developed at a leading healthcare organization, and current clinical data demonstrates higher confirmation accuracy than clinical judgment alone — a finding recognized by the FDA, which states the Capnospot is \"used for more accurate placement of pneumothorax decompression devices than the current standard of care auditory assessments.\"\u003c\/p\u003e\n\n  \u003c!-- Why Objective Confirmation Matters --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eThe Problem with Auditory Confirmation\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eLimitation\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eAuditory (\"Hiss\") Method\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eCapnospot CO₂ Method\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNoise environment\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSeverely degraded by helicopter, gunfire, crowds\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eUnaffected — visual, not auditory\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSubjectivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eHigh — depends on operator perception\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eNone — objective color change (blue → yellow)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMissed catheter loss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNot detected\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eCapnospot reverts to blue — immediate alert\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eLow-light use\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eAuditory only — unaffected\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eReadable in low-light conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eConfirmation speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eImmediate if tension is large enough\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e\u0026lt;5 seconds — even for smaller tension volumes\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eEvidence base\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eLong-standing clinical practice\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eClinical data; FDA-recognized accuracy improvement; 2023 EMS World Expo Innovation Award\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- How to Use --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eHow to Use the Capnospot\u003c\/h2\u003e\n  \u003col style=\"margin:0 0 24px;padding-left:20px;font-size:15px;line-height:1.8;\"\u003e\n    \u003cli\u003eAttach the Capnospot to the distal (hub) end of your decompression needle or catheter via standard Luer connection prior to insertion\u003c\/li\u003e\n    \u003cli\u003ePerform needle decompression per TCCC protocol (perpendicular to chest wall, to the hub)\u003c\/li\u003e\n    \u003cli\u003eObserve the indicator: color change from blue → yellow within 5 seconds confirms pleural entry and successful decompression\u003c\/li\u003e\n    \u003cli\u003eIf the indicator remains blue, the needle has not entered the pleural space — reposition or attempt at the alternate site with a new needle\/catheter unit\u003c\/li\u003e\n    \u003cli\u003eMonitor during dwell: if the indicator reverts to blue after initial yellow confirmation, catheter patency may be lost — reassess and reposition\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003c!-- Clinical Data Summary --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eClinical Data Summary\u003c\/h2\u003e\n  \u003cul style=\"margin:0 0 24px;padding-left:20px;font-size:15px;line-height:1.8;\"\u003e\n    \u003cli\u003eTension pneumothorax: 100% fatality if untreated — among the most time-critical reversible trauma emergencies\u003c\/li\u003e\n    \u003cli\u003eNeedle thoracostomy failure rate: 20–50% in well-trained professionals (published literature)\u003c\/li\u003e\n    \u003cli\u003eSuccessful therapy: associated with approximately 25% reduction in 24-hour mortality\u003c\/li\u003e\n    \u003cli\u003eCapnospot confirmation speed: \u0026lt;5 seconds from pleural entry\u003c\/li\u003e\n    \u003cli\u003eRecognition: Winner, 2023 EMS World Expo Innovation Award; FDA-recognized accuracy improvement over auditory assessment\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003c!-- Related Products --\u003e\n  \u003cp style=\"margin:0 0 32px;font-size:15px;\"\u003ePair the Capnospot with the \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/chest-thoracic-supplies\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eNAR ARS® or SPEAR® needle decompression devices\u003c\/a\u003e for a complete, objective needle thoracostomy system. Browse the full \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/chest-thoracic-supplies\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eChest \u0026amp; Thoracic Supplies\u003c\/a\u003e collection or explore \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/respiratory-support\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eRespiratory Support\u003c\/a\u003e products.\u003c\/p\u003e\n\n  \u003c!-- Compliance Footer --\u003e\n  \u003cp style=\"margin:24px 0 0;padding:12px 16px;background:#f5f4f0;border-left:3px solid #9c8f61;font-size:13px;color:#555;line-height:1.5;\"\u003eAll products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Pneumeric","offers":[{"title":"Default Title","offer_id":40174670151798,"sku":null,"price":50.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/products\/capnospot-pneumothorax-decompression-indicator-9945838.jpg?v=1763154877","url":"https:\/\/www.tactical-medicine.com\/en-au\/products\/capnospot-pneumothorax-decompression-indicator","provider":"MED-TAC International Corp.","version":"1.0","type":"link"}