{"product_id":"save-ii-ventilator-kit-w-emma-r-capnograph-helicopter-starter-set","title":"SAVe II+™ Ventilator Kit w\/ EMMA® Capnograph Helicopter Starter Set","description":"\u003c!-- SAVe II+ Ventilator Kit w\/ EMMA Capnograph Helicopter Starter Set — GEO-optimized product description --\u003e\n\u003cdiv style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#121212;max-width:860px;margin:0 auto;line-height:1.65;\"\u003e\n\n  \u003c!-- Direct Answer Block --\u003e\n  \u003cdiv style=\"margin:0 0 28px;padding:16px 20px;background:#f5f4f0;border-left:4px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0;font-size:15px;color:#121212;line-height:1.6;\"\u003eThe AutoMedX SAVe II+™ Ventilator Kit with EMMA® Capnograph Helicopter Starter Set is a complete aeromedical and ground EMS ventilation bundle combining the SAVe II+ portable mechanical ventilator with the Masimo EMMA® mainstream capnograph for continuous end-tidal CO₂ monitoring. Designed specifically for helicopter EMS (HEMS), critical care transport, and prehospital teams requiring integrated ventilation and waveform capnography in a single, field-ready package. SKU 70110H-CH.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specifications Table --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eKey Specifications — SAVe II+ Ventilator\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eParameter\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eAutoMedX (Ventilator) | Masimo (EMMA® Capnograph)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e70110H-CH\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eOperating Mode\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eA\/C-CMV — Time cycled, pressure limited, volume targeted\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eTidal Volume\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e200–800 mL (preset: 6 mL\/kg IBW by height selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eRespiratory Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e8–30 breaths per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePeak Inspiratory Pressure (PIP)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e10–60 cmH₂O\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003ePEEP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e0–20 cmH₂O (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eFiO₂\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e21–100% (0–12 LPM supplemental O₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e8.25–9.25 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eVentilator Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e6.5\" × 6.25\" × 2.0\" | 2.8 lbs (1.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eVent IP24 | Case IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePreset Heights\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e4'3\" – 6'3\" in 3-inch increments\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- EMMA Capnograph Specs --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eKey Specifications — EMMA® Capnograph (Masimo)\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eParameter\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMasimo (EMMA® Capnograph)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eQuantitative mainstream EtCO₂ with waveform capnography\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eCO₂ Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e0–99 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eCO₂ Accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e0–40 mmHg: ±2 mmHg | 41–99 mmHg: ±6% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eRespiratory Rate Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e3–150 breaths per minute | Accuracy: ±1 BPM\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e2 × AAA Alkaline (6 hr) or Lithium (10 hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e-5°C to 50°C (23°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePatient Population\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eAdult, pediatric, and infant\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eAirway Adapter Dead Space\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e6 mL (Adult\/Pediatric) | 1 mL (Infant)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePalm-sized, handheld; simple 1-button operation; audible and visual alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eProduct Overview\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eHelicopter EMS (HEMS), critical care transport, and ground ALS operations managing intubated patients face two concurrent ventilation challenges: delivering consistent, safe mechanical ventilation while simultaneously monitoring ventilation quality. Noise, vibration, altitude-induced physiology changes, and limited physical space inside transport vehicles compound the difficulty of both tasks when performed manually or with separate unintegrated devices.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe AutoMedX SAVe II+™ Ventilator Kit with EMMA® Capnograph Helicopter Starter Set solves both challenges in a single, coordinated package purpose-engineered for aeromedical and critical care transport use. The SAVe II+ provides automated, consistent mechanical ventilation — freeing the flight medic from manual BVM ventilation — while the EMMA® capnograph provides continuous quantitative EtCO₂ monitoring with waveform display, enabling real-time respiratory assessment and immediate detection of tube displacement, circuit disconnection, or hyperventilation.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe clinical rationale for combining these two technologies is well-established: current EMS and critical care transport protocols require both mechanical ventilation and continuous capnography for intubated patients in transport. Hyperventilation during transport — caused by excessive manual BVM rates or provider fatigue — is a significant cause of secondary brain injury in TBI patients and cardiovascular instability in polytrauma. The SAVe II+'s consistent rate and volume delivery, combined with EMMA® continuous EtCO₂ monitoring, eliminates inadvertent hyperventilation and ensures ventilation remains within target parameters throughout the transport mission.\u003c\/p\u003e\n\n  \u003c!-- Why This Kit for HEMS \/ Critical Care Transport --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eWhy This Kit for Aeromedical \u0026amp; Critical Care Transport\u003c\/h2\u003e\n\n  \u003cdiv style=\"margin:0 0 20px;padding:14px 18px;background:#f5f4f0;border-left:3px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0 0 6px;font-size:15px;font-weight:700;\"\u003ePEEP for Altitude Physiology\u003c\/p\u003e\n    \u003cp style=\"margin:0;font-size:14px;\"\u003eAt altitude, reduced atmospheric pressure can worsen alveolar collapse in patients with respiratory compromise. The SAVe II+'s adjustable PEEP (0–20 cmH₂O) allows flight medics to set positive end-expiratory pressure to maintain alveolar recruitment and optimize oxygenation at altitude — a capability not available with manual BVM ventilation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"margin:0 0 20px;padding:14px 18px;background:#f5f4f0;border-left:3px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0 0 6px;font-size:15px;font-weight:700;\"\u003eEtCO₂ Monitoring: TBI and Hemodynamic Optimization\u003c\/p\u003e\n    \u003cp style=\"margin:0;font-size:14px;\"\u003eFor patients with traumatic brain injury (TBI), maintaining EtCO₂ between 35–45 mmHg is critical to preventing secondary brain injury from hyper- or hypoventilation-induced changes in cerebrovascular resistance. The EMMA® capnograph with waveform display allows the flight medic to titrate the SAVe II+'s respiratory rate in real time based on continuous EtCO₂ feedback — a level of precision not achievable with manual ventilation alone.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"margin:0 0 20px;padding:14px 18px;background:#f5f4f0;border-left:3px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0 0 6px;font-size:15px;font-weight:700;\"\u003eTube Displacement Detection\u003c\/p\u003e\n    \u003cp style=\"margin:0;font-size:14px;\"\u003eEndotracheal tube displacement is a critical, potentially fatal complication during transport. The EMMA® capnograph provides immediate warning of tube displacement through loss of the EtCO₂ waveform — before SpO₂ desaturation (which lags tube displacement by minutes) would alert the provider. In a helicopter environment with limited space and constant vibration, continuous capnographic confirmation of tube position is a standard-of-care requirement.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"margin:0 0 20px;padding:14px 18px;background:#f5f4f0;border-left:3px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0 0 6px;font-size:15px;font-weight:700;\"\u003eIP67 Case + IEC Vibration\/Shock Certification\u003c\/p\u003e\n    \u003cp style=\"margin:0;font-size:14px;\"\u003eThe SAVe II+'s IP67-rated protective case provides dust-tight and waterproof protection for transport in any environment. IEC 60068-2-6 and 60068-2-36 vibration and shock certification ensures reliable operation through the vibration profiles typical of helicopter and ground vehicle transport.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Who This Kit Is For --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eIdeal Users and Settings\u003c\/h2\u003e\n  \u003cul style=\"margin:0 0 24px;padding-left:20px;font-size:15px;line-height:1.8;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHEMS programs:\u003c\/strong\u003e Purpose-built helicopter starter set with capnography integration; replaces fragmented individual device procurement\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCritical care transport teams:\u003c\/strong\u003e Ground CCT crews managing ventilator-dependent patients during inter-facility or scene-to-hospital transport\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMilitary aeromedical evacuation:\u003c\/strong\u003e Compact 2.8 lb footprint + 9.25 hr battery life for extended CASEVAC\/MEDEVAC missions without generator power\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCombat support hospitals \/ Role 2 and Role 3 facilities:\u003c\/strong\u003e Ventilator surge capability with integrated EtCO₂ monitoring for mass casualty scenarios\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEmergency medical directors equipping EMS agencies:\u003c\/strong\u003e One-bundle procurement for agencies adding mechanical ventilation + capnography capability simultaneously\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003c!-- Related Products --\u003e\n  \u003cp style=\"margin:0 0 32px;font-size:15px;\"\u003eAlso available as the standalone \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/respiratory-support\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eSAVe II+ Simplified Automated Ventilator (SKU 70110H)\u003c\/a\u003e without the EMMA capnograph. Pair with \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/airway-management-kits-and-supplies\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eAirway Management Kits\u003c\/a\u003e for complete airway-to-ventilation capability, or explore the full \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/respiratory-support\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eRespiratory Support\u003c\/a\u003e collection.\u003c\/p\u003e\n\n  \u003c!-- Compliance Footer --\u003e\n  \u003cp style=\"margin:24px 0 0;padding:12px 16px;background:#f5f4f0;border-left:3px solid #9c8f61;font-size:13px;color:#555;line-height:1.5;\"\u003eAll products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"AutoMedX","offers":[{"title":"Default Title","offer_id":41865730228342,"sku":"70110H-CH","price":10750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/files\/save-ii-ventilator-kit-w-emma-capnograph-helicopter-starter-set-3899602.png?v=1780705647","url":"https:\/\/www.tactical-medicine.com\/products\/save-ii-ventilator-kit-w-emma-r-capnograph-helicopter-starter-set","provider":"MED-TAC International Corp.","version":"1.0","type":"link"}