What is the MED-TAC Oxygen Cylinder Size D? The MED-TAC Oxygen Cylinder Size D (SKU: LX-Cylinder) is a portable 14.6 cubic foot (approximately 415 liter) medical oxygen tank with a CGA870 post valve installed. Weighs approximately 7 lbs. Requires a separate oxygen regulator (such as the MED-TAC Mini O2 Regulator). Provides approximately 27 minutes at 15 LPM or approximately 69 minutes at 6 LPM. The standard portable oxygen cylinder for pre-hospital, EMS, and tactical medical oxygen therapy.
Key Specifications
| Specification | Detail |
|---|---|
| Manufacturer / Vendor | MED-TAC International |
| SKU | LX-Cylinder |
| Cylinder Size | D (standard portable medical oxygen) |
| Capacity | 14.6 cubic feet (~415 liters of medical oxygen) |
| Valve Type | CGA870 post valve (installed) |
| Weight | ~7 lbs |
| Regulator | Requires CGA870 regulator — NOT included |
| Duration at 15 LPM (NRB/BVM) | ~27 minutes |
| Duration at 10 LPM (NRB) | ~41 minutes |
| Duration at 6 LPM (face mask) | ~69 minutes |
| Duration at 2 LPM (cannula) | ~207 minutes |
| Gas | Medical-grade oxygen (O₂) |
Product Overview
The Size D oxygen cylinder is the most common portable medical oxygen cylinder used in EMS, pre-hospital care, and clinical transport environments. Balancing capacity against portability, the D cylinder provides adequate oxygen for patient care during short transport times without the bulk of larger hospital cylinders. The CGA870 post valve is the U.S. standard for portable medical oxygen, ensuring compatibility with all standard medical oxygen regulators.
At 14.6 cubic feet (approximately 415 liters) of medical oxygen at standard pressure, the Size D cylinder provides meaningful oxygen therapy duration across clinical delivery scenarios. At 15 LPM (non-rebreather mask or BVM reservoir), the cylinder supports approximately 27 minutes of high-flow oxygen — sufficient for most ground transport scenarios. Lower flow rates for nasal cannula or simple face mask extend duration significantly.
This cylinder ships empty and must be filled with medical-grade oxygen by an authorized medical gas supplier before use. Oxygen cylinders must be handled, stored, and transported in accordance with CGA and DOT regulations for compressed medical gases. Always inspect cylinders for damage, verify fill level before patient use, and ensure regulators are properly secured before transport.
- Cylinder: Size D Oxygen Cylinder (LX-Cylinder) — this product
- Regulator: Mini O2 Regulator (MEDTAC1110) — CGA870, 0–15 LPM
- High-flow delivery: Non-Rebreather Mask (LX-NRB) — 60–80% FiO2 at 10–15 LPM
- Low-flow delivery: Nasal Cannula (MEDTAC1109) — 24–44% FiO2 at 1–6 LPM
See MED-TAC's complete airway management collection for all oxygen delivery and airway management supplies.
All products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.
Specifications coming soon. Contact us for detailed product information.